Clinical effect of cone-beam computed tomography-guided radiotherapy for malignant tumors

  • LI Wei ,
  • WANG Chunyan ,
  • ZHOU Shixiang
Expand
  • The First Affiliated Hospital of Bengbu Medical College, Bengbu 233000, China

Received date: 2024-04-15

  Online published: 2024-12-24

Abstract

Objective: To analyze the effect of cone-beam computed tomography (CBCT) guided radiotherapy for malignant tumors. Methods: A total of 68 patients with malignant tumors who received radiotherapy from October 2021 to October 2022 were selected as the research objects. They were randomly divided into observation group and control group. Among them, 34 patients in the observation group received CBCT-guided radiotherapy, with a frequency of 1 time/d. 34 patients in the control group also received CBCT-guided radiotherapy, with a frequency of 1 time/3 d. The clinical effects of CBCT-guided methods were compared and analyzed. Results: The absolute values of x, y, z axis setup errors and setup expansion boundary in the observation group were lower than those in the control group (P<0.05). The maximum irradiation dose and average irradiation dose of malignant tumor patients in the gross tumor area and planned target area in the observation group were higher than those in the control group (P<0.05). The objective effective rate of the observation group was higher than that of the control group (P<0.05). The quality of life scores in all fields of the observation group were higher than those of the control group (P<0.05). Conclusion: For patients with malignant tumors, CBCT scanning and guidance before treatment can reduce the positioning error during radiotherapy. With the increase of CBCT scanning frequency, the adaptability and accuracy of radiotherapy can be better improved, the treatment effect can be ensured, and the discomfort reaction can be prevented.

Cite this article

LI Wei , WANG Chunyan , ZHOU Shixiang . Clinical effect of cone-beam computed tomography-guided radiotherapy for malignant tumors[J]. Journal of Baotou Medical College, 2024 , 40(12) : 68 -71 . DOI: 10.16833/j.cnki.jbmc.2024.12.013

References

[1] 李治斌,钟仁明,柏森. 4D CBCT在胸部肿瘤影像引导下自动配准精度及其影响分析[J]. 四川大学学报(医学版), 2020, 51(6):834-838.
[2] 侯利桥,周超,许韵宇,等. 基于CBCT影像组学与常规CT影像组学分析早期肺癌SBRT早期反应的一致性[J]. 肿瘤学杂志, 2020, 26(3):250-253.
[3] 俞雅,许青,韩序,等. 锥形束CT图像引导在盆腔肿瘤患者调强放射治疗中位置误差测定的应用分析[J]. 中国医学装备, 2020, 17(12):48-51.
[4] 蒋振东,谢有海,马天斌,等. 利用CBCT图像监测鼻咽癌放疗腮腺和外轮廓体积变化[J]. 实用癌症杂志, 2020, 35(6):944-946.
[5] 何赟,李毅,王亚利,等. 锥形束CT宫颈癌调强放疗中膀胱充盈程度对膀胱实际剂量及靶区影响的评估[J]. 西部医学, 2021, 33(9):1326-1331.
[6] 梁卫学,韦顺文,李代学,等. 基于CBCT的体表标记点辅助配准方法在体部肿瘤放疗摆位中的应用研究[J]. 现代肿瘤医学, 2022, 30(11):2046-2050.
[7] 李明,吴建亭,王君辉,等. 肿瘤放射治疗中图像引导方式研究进展[J]. 生物医学工程与临床, 2022, 26(5):652-657.
[8] 江桓宇. 计算机导航与CT引导下经皮穿刺椎体成形中放射治疗椎体恶性肿瘤的效果观察[J]. 基层医学论坛, 2022, 26(17):130-132.
[9] 王硕,董量,刘启为,等. 锥形束CT图像引导技术对降低肺癌放疗患者放射性肺损伤发生风险的影响[J]. 中华肿瘤防治杂志, 2021, 28(10):765-769, 775.
Outlines

/