Objective: To prepare the targeted lipid-microbubble ultrasonographic contrastagent loaded with paclitaxel LHRH, and to evaluate its physical and chemical properties,Methods:LHRH targeted lipid-microbubble was prepared by Co-evaporating method, mechanical vibration method and biotin-avidin method. The size and surface electric potential were detected by Malvern detector and the imaging was observed by ultrasonography. The drug-loading capacity and encapsulation rate were determined by high performance liquid chromatography (HPLC). The connection rates of secondary antibody with targeted and non-targeted lipid-microbubble were detected by flow cytometry (FCM).Results: The targeted lipid- microbubble had complete appearance and even distribution. After being kept at room temperature for 14 days, there was no significant difference of general properties ( P>0.05). The binding rates of secondary antibody with targeted and non-targeted lipid-microbubble were 97.76±2.18 % and 6.48±0.71 % respectively, which had significant difference (P<0.05).Conclusion: The targeted lipid-microbubble loaded with paclitaxel is successfully prepared, with smaller size and higher stability. It has a high connection rate of LHRH.
MA Lan
,
YAN Guozhen
,
HE Junfeng
,
WEN Qing
. Study in preparation of lipid-microbubble ultrasonographic contrastagent loaded with paclitaxel LHRH and its properties[J]. Journal of Baotou Medical College, 2017
, 33(9)
: 129
-131
.
DOI: 10.16833/j.cnki.jbmc.2017.09.054
[1] Jelovac D,Armstrong DK.Recent progress in the diagnosis and treatment of ovarian cancer[J].CA Cancer J Clin, 2011,61(3):183-203.
[2] Saad M,Garbuzenko OB,Ber E,et a1.Receptor targeted polymers,dendrimers,liposomes:which nanocarrier is the most efficient for tumor-specific treatment and imaging?[J].Control Release,2008,130(2):107-114.
[3] 郝权,田菁,王耕辛.卵巢癌靶向治疗研究进展[J].中国肿瘤临床,2005,32(22):1315-1318.
[4] Ward M, Wu J, Chiu JF.Experimental study of the effects of Optison concentration on sonoporation in vitro[J].Ultrasound Med Biol.2000,26(7):1169-1175.
[5] Bast RC,Skates S,Lokshin A,et al.Differential diagnosis of apelvic mass:Imp Roved algorithms and novel biomarkers.Int J Gynecol Cancer,2012,22Suppl 1(1):S5-S8.
[6] 陈智毅,谢明星.超声靶向破坏微泡技术的应用进展[J].中国医学影像技术,2010,26(9):1790-1792.
[7] 王冬,谭开彬,杨珂,等.纳米级超声微泡造影剂的制备及其性状的初步研究[J].临床超声医学杂志,2007,(12):709-711.
[8] Willmann JK,Paulmurugan R,Chen K,et al.US imaging of tumor angiogenesis with microbubbles targeted to vascular endothelial growth factor receptor type 2 in mice[J].Radiology,2008,246(2):508-518.
[9] Engel JB,Schally AV,Buchholz S,et al.Targeted chemotherapy of endometrial,ovarian and breast cancers with cytotoxic analogs of luteinizing hormone-releasing hormone (LHRH)[J].Arch Gynecol Obstet,2012,286(2):437-442.
[10] 贺娟,孙江川,常淑芳,等.人卵巢癌靶向超声造影剂的制备及其体外寻靶能力观察[J].中国医学影像技术,2009,25(6):929-931.
[11] Reches M,Gazit E.Biological and chemical decoration of peptide nanostructures via biotin-avidin interactions[J].J Nanosci Nanotechnol,2007,7(7):2239-2245.