Objective: To explore the related problems and intervention methods of blunt needle buttonhole technique in the long-term of autologous arteriovenous fistula puncture and analysis its effect, so as to provide guidance and reference for clinical nursing in hemodialysis. Methods: Clinical data of 267 hemodialysis patients who received arteriovenous fistula puncture with the blunt needle buttonhole technique in yijishan hospital, the First Affiliated Hospital of Wannan Medical College were reviewed. Reasons for the formation of the buttonhole false tunnel, the methods and skills of removing the scab at the buttonhole point were summarized, and risk factors of the internal fistula infection during the buttonhole puncture were analyzed to provide prevention methods. Results: Among the 267 patients, 189 patients underwent blunt needle puncture with both arterial and venous needles, and 78 patients underwent blunt needle puncture with only one needle of arterial puncture or venous puncture. Tunnel reconstruction with buttonhole was performed in 17 cases. From July to September 2019 and October to December 2019, a disposable No.16 sterile round blunt needle and a disposable No. 12 sterile beveled sharp needle were respectively used to remove the scabs after wet compressing the punctured sites. There was no statistical difference in the occurrence of bleeding between the two methods(P>0.05); However, the degree of difficulty in removing scabs was statistically higher in the former than in that the latter (P<0.001), and the frequency of infection was statistically higher in the former than that in the latter (P<0.05). Conclusion: When false tunnel formed and scab hard to remove in buttonhole puncture, reconstruction of the original buttonhole tunnel with sharp needle and remove the scab after wet compression of the puncture hole by using disposable No.12 sterilized inclined needle can improve the success rate of vascular puncture and avoid infection at the puncture site. It has certain clinical value in the maintenance of long-term vascular access in hemodialysis patients and is worth of popularizing.
WANG Cuizhen
,
LIU Huan
,
TAO Mingfen
,
XU Yan
,
LIU Jun
,
LING Zhangbin
. Application of blunt needle buttonhole reconstruction technique and escharectomy tool in autogenous arteriovenous fistula puncture[J]. Journal of Baotou Medical College, 2024
, 40(1)
: 57
-61
.
DOI: 10.16833/j.cnki.jbmc.2024.01.010
[1] 严锦, 刘永岚. 自体动静脉内瘘穿刺的护理研究进展[J]. 护理实践与研究, 2018, 15(14): 24-25.
[2] 金其庄, 王玉柱, 叶朝阳, 等. 中国血液透析用血管通路专家共识(第2版)[J]. 中国血液净化, 2019, 18(6): 365-381.
[3] 周建芳, 叶晓敏, 黄春香, 等. 自体动静脉内瘘扣眼穿刺感染的分析及预防[J]. 中华医院感染学杂志, 2017, 27(7): 1659-1662.
[4] Ogawat T, Haradae E, Kanayamay Y, et al. The impact of buttonhole cannuation on patients and staff in hemodialysis facil-ities[J]. Contrib Nephrol, 2015, 186: 13-20.
[5] 陶明芬, 王翠珍, 许燕, 等. 钝针扣眼穿刺技术在自体动静脉内瘘中的应用[J]. 皖南医学院学报, 2016, 35(2): 198-199, 202.
[6] 王婧, 矫健梅, 彭影, 等. 48例钝针扣眼穿刺法在血液透析患者动静脉内瘘中的实施与效果分析[J]. 中国血液净化, 2018, 17(4): 268-271.
[7] 林晓玲, 黄海燕, 黄彩云. 影响动静脉内瘘扣眼穿刺失败的原因分析及应对措施[J]. 中国实用医药, 2019, 14(1): 186-187.
[8] Galante NZ, Rabelo LL, Yamamoto A, et al. One unit’s experiences when establishing buttonhole technique, analysis of reasons for failure of procedure: a report[J]. J Ren Care, 2010, 36(2): 73-80.
[9] 张晓玲, 高菊林, 柳淑惠, 等. 三种去痂法在血液透析扣眼穿刺患者中的去痂效果[J]. 临床医学研究与实践, 2019, 4(30): 159-160.
[10] 缪鹏亮, 朱唯一. 钝针扣眼穿刺技术在血液净化应用中的并发症及其影响因素[J]. 解放军护理杂志, 2020, 37(1): 71-73.